اعلام حریق
XFP Addressable Fire Panels
Key XFP features (available across the range) include: _ Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB) _ Full compatibility with Hochiki’s ESP and Apollo’s XP95/Discovery protocols (dependent on model purchased). _ Two independently programmable conventional sounder circuits _ Two programmable inputs _ A fault output relay and three programmable relay outputs with voltage free changeover contacts _ A selection of zone dependency/coincidence functions _ A day/night
پنل اعلام حریق C-TEC MFP 4-28 Zone BS Fire Panel
Key MFP features: تطابق با استاندارد BS5839 دارای درب و بدنه فلزی محکم داراب نمایشگر LED با عمر بالا دارای منبع تغذیه و شارژ باطری 24 ولت سازگاری با انواع دتکتور دود و حرارت امکان استفاده از خط سه سیمه جهت اتصال به انواع آژیر و دتکتور دارای نمایشگر Fault جداگانه برای حالتهای اتصال کوتاه و قطعی و آلارم و ایراد در منبع تغذیه دارای آژیر غیر دائم جهت اعلام خرابی ها و آژیر دائم
پنل اعلام حریق C-TEC CFP 2-8 Zone LPCB Fire Panel
پنل اعلام حریق متعارف C-TEC سری CFP 2-4-8 هر جا سخن از قیمت مناسب، طراحی حرفه ای و تجهیزات الکترونیکی قابل اعتماد است تنها با C-TEC امنیت خواهید داشت کلیه محصولات اعلام حریق، آژیر، سیستم های تلفن کننده و … با سطحی از کیفیت طراحی و ساخته شده اند که گارانتی کردن کلیه محصولات را برای ما ممکن می کنند. بخشی از افتخارات ما، تاسیس کمپانی در سال ۱۹۸۱ و گسترش تجارت
پنل اعلام حریق C-TEC
هر جا سخن از قیمت مناسب، طراحی حرفه ای و تجهیزات الکترونیکی قابل اعتماد است تنها با C-TEC امنیت خواهید داشت کلیه محصولات اعلام حریق، آژیر، سیستم های تلفن کننده و … با سطحی از کیفیت طراحی و ساخته شده اند که گارانتی کردن کلیه محصولات را برای ما ممکن می کنند. بخشی از افتخارات ما، تاسیس کمپانی در سال 1981 و گسترش تجارت جهانی در بیش از 60 کشور دنیا
Apollo Series 65 Heat Detectors
The heat detector operates by using a matched pair of thermistors to sense heat.One thermistor is exposed to the ambient temperature, the other is sealed.In normalconditions, the two thermistors register similar temperatures, but, on the development of a fire, the temperature recorded by the exposed thermistor will increase rapidly, resulting in an imbalance of the thermistors and causing the detector to change to the alarm state. A1R, BR and CR
Series 65 Optical Smoke Detector
The optical smoke detector uses an internal pulsing LED and a photo-diode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered and registered by the photo-diode. The detector will then enter the alarm state and the indicator LED lights up.
Series 65 Ionisation Smoke Detector
Air in the dual sensing chambers is irradiated to produce ions that travel to the positive and negative electrodes, creating a current flow. As smoke enters the outer chamber, the flow drops and the voltage increases. The detector will then enter the alarm state and the indicator LED lights up. An intergrating ionisation detector, suitable for use in areas where transient high levels of smoke may be expected, is
KLAXON Sonos Sounder (AC)
Dual Voltage 110V AC or 230V AC Smooth flow cabling for faster installation Up to 106dB (A) @ 1 metre Weatherproof to IP65 …
KLAXON Sonos Sounder Beacon (AC)
Dual voltage 110V AC or 230V AC Up to 102dB (A) @ 1 metre No locking screw required Weatherproof to IP65 Choice of lens colours LED beacon Smooth flow cabling for faster installation